IIC - 120   HIGH TEMP. OIL BATH
Precisefor oxidation stability Test on Oil & Grease

Useful for Calibration of Thermometer & Thermocouple.

Better Mineral/Cerablanket Insulated to avoid loss of heat & gives better result.

Polish/Hair Line 304 grade heavy steel sheet duly argon welded to avoid leakage at high Temp, during Test.

Diffuser plate forthe safe handling during test.

Kanthal 1 special S. S. quality Oil Heaters are fitted to cover oil Bath & gives uniform/ heat Temp. Throughout the Chamber.

Full feature Digital Temperature Controller Cum Indicator & Microprocessor based PID Temp. Controller can be made (on Customer request).

Best quality Bi-Metallic capillaryThermostat can be fitted in place of Digital Temp. Controller / PID Controller (On Customer request).

Best quality 1/20 HP stirrer is fitted on the backside for uniform circulation of liquid & Temperature Bath.

Applications:
Use for Research & Calibration, Educational Engg. College, Biotech Lab._
Models IIC 120 IIC 120 A IIC 120 B
Capacity (L) 12 Ltrs. 18 Ltrs. 20 Ltrs.
Interior (mm) 200x250x250 300x250x250 300x300x250
Wattage "W" 1.5 KW 2.0 KW 2.0 KW
Diffuser Plate / Shelves 01 No. 01 No. 01 No.
Models IIC 120 IIC 120 A IIC 120 B
Capacity (L) 12 Ltrs. 18 Ltrs. 20 Ltrs.
Interior (mm) 200x250x250 300x250x250 300x300x250
Wattage "W" 1.5 KW 2.0 KW 2.0 KW
Diffuser Plate / Shelves 01 No. 01 No. 01 No.
Technical Parameters :
  • Temperature : Ambient to 250 o C.
  • Temperature Stability : ±2o C.
  • Control Panel :Mains Indicator load indicator speed regulator, Temp.Controller
  • Digital setting : 1o C.
  • Digital resolution : 1o C.
  • Optional : All S.S Outer & Inner body (on customer requirement)
  • Interior : S.S. 304 grade as per requirement
  • Power Consumption : 220/230V AC ±10%, 50HZ
  • Duty Cycle : COntinous
  • Housing Material :CRC/MS Sheet body duly powder coated.



IIC - 121   DIGITAL COLONY COUNTER
Useful forcountlng Bacterial mould In culture Test/Work.

Provide uniform glaze free illumination to minimize the strain on eyes

Clearly defines even small colonies.

A100mm (4") dia lens covers the entire illumination field &its magnification assures high quality results.

Counting plates with (Wo f hugel) ruling ensures clearly differentiated & shapely defined Colonies.

Supplied with counting plate, Plate, Lens, Counting Pen & its cover

Full feature digitally controlled.

Outer casing CRC/MS sheet duly powder coated.

Applications:
Bio Tech Research, Medical Pharmaceutical & Educational Institute
Models IIC 121 IIC 121 A
3 Digit 4 Digit
Technical Parameters :
  • Power Consumption : 220/230V AC supply 50HZ
  • Material : CRC / MS Sheet duly powder coated
  • Duty cycle : continuous
  • Control Panel : MAins & Reset Switch & Fuse.