Home » Pathology Testing Instruments

Pathology Testing Instruments


IIC - 623   MICROPIPETTE VARIABLE PRIME



IIC - 624   MICROPIPETTE VARIABLE ROUTINE
Volume Range (ul) Volume (ul)
0.2 - 2.0 0.2
1.0
2.0
0.5-10.0 3.5
5.0
1C.0
2.0 - 20.0 2.0
10.0
210
5.0 - 50.0 5.0
25.0
50.0
10.0-100.0 1 z.o
50.0
oc.o
20.0-200.0 20.0
10O.0
20O.0
'00.0 - 1000.0 10O.0
50O.0
1000.0
500.0-5000.0 500.0
2500.0
5000.0
1000.0-10000.0 1000.0
5000.0
10000.0



IIC - 625   DOUBLE BED DEMINERALISER MODEL
Consists of: Inbuilt prefilter. high exchanging capacity cation and anion resin columns, Conductivity meter-operates on AC

One PVC chemical proof regeneration tank.

A set of flexible polythene tube connection, all housed inatrolly mounted, corrosion tube mild steel stand for mobility. Deionised or Demineralised water will have the conductivity of less then 10 microsiemens / cm. and pH of 7.5 to 9



IIC - 626   FOUR BED DEMINERALISER
Consists of: Inbuilt prefilter, Activated carbon cation and anion resin columns, Digital meter operates on AC, PVC chemical proof regeneration tank.

A set of flexible polythene tube connection, al housed in a trolly mounted chemical proof M.S. Stand - easily portable-rugged construction to withstand any external accidents and chemical corrosions.

Deionised or Demineralised water will have the conductivity of less then lOmicrosiemens/cm.and pHof7.5to9
Modal No. IIC-626 A IC-626 B IIC-626 C IIC-626 D IIC-626 E |
Output /hr. in Liters 100 200 300 500 750
Price 35,000.00 49.ODO.00 70,000.00 78,000.00 92,000.00
Modal No. IIC-626 A IC-626 B IIC-626 C IIC-626 D IIC-626 E |
Output /hr. in Liters 100 200 300 500 750
Price 35,000.00 49.ODO.00 70,000.00 78,000.00 92,000.00



IIC - 627   MIX BED DEMINERALISER
To produced IPgrade deionised water and to bring down the dissolved solids to less than 1 mg/lit.

Consists of: Mixed anion resin columns , digital conductivity meter, diaphragm type PP valves. A set of flexible polythene tubing, one PVC regeneration tank. One ADS (Air Displacement System) drum for rasin mixing.

The rasin column and valves are housed in an attractive stand attached with two castors for mobility.

Normally this MB unit IIC-IS operated as a polishing unit running in series with IIC-DB or IIC-FB model demineraliser.

Deionised water will have the conductivity of less then 1 ms /cm, and pH of
Model No. IK-627A IC-627 B IIC-627C IIC-627 D IIC-627 E
Output/hr. in Liters 100 200 300 500 750
Price 30,000.00 42,000.00 53,000.00 73,000.00 87,000.00
Model No. IK-627A IC-627 B IIC-627C IIC-627 D IIC-627 E
Output/hr. in Liters 100 200 300 500 750
Price 30,000.00 42,000.00 53,000.00 73,000.00 87,000.00

Note: Model IIC-627D and above needminiaircompressorfor resin mixing and this has to bearranged by the customer on theirown.ln case if they want the same from us it will be supplied at extra cost.