IIC - 120
HIGH TEMP. OIL BATH
Precisefor
oxidation stability Test on Oil & Grease
Useful for Calibration of Thermometer &
Thermocouple.
Better Mineral/Cerablanket Insulated to
avoid loss of heat & gives better result.
Polish/Hair Line 304 grade heavy steel
sheet duly argon welded to avoid leakage at high Temp, during Test.
Diffuser plate forthe safe handling
during test.
Kanthal 1 special S. S. quality Oil
Heaters are fitted to cover oil Bath & gives uniform/ heat Temp.
Throughout the Chamber.
Full feature Digital Temperature
Controller Cum Indicator & Microprocessor based PID Temp. Controller can
be made (on Customer request).
Best quality Bi-Metallic
capillaryThermostat can be fitted in place of Digital Temp. Controller / PID
Controller (On Customer request).
Best quality 1/20 HP stirrer is fitted
on the backside for uniform circulation of liquid & Temperature Bath.
Applications:
Use for Research & Calibration, Educational Engg. College, Biotech
Lab._
|
Models |
IIC 120 |
IIC 120 A |
IIC 120 B |
Capacity (L) |
12 Ltrs. |
18 Ltrs. |
20 Ltrs. |
Interior (mm) |
200x250x250 |
300x250x250 |
300x300x250 |
Wattage "W" |
1.5 KW |
2.0 KW |
2.0 KW |
Diffuser Plate / Shelves |
01 No. |
01 No. |
01 No. |
|
|
|
Models |
IIC 120 |
IIC 120 A |
IIC 120 B |
Capacity (L) |
12 Ltrs. |
18 Ltrs. |
20 Ltrs. |
Interior (mm) |
200x250x250 |
300x250x250 |
300x300x250 |
Wattage "W" |
1.5 KW |
2.0 KW |
2.0 KW |
Diffuser Plate / Shelves |
01 No. |
01 No. |
01 No. |
|
|
Technical Parameters :
- Temperature : Ambient to 250 o C.
- Temperature Stability : ±2o C.
- Control Panel :Mains Indicator load indicator speed regulator,
Temp.Controller
- Digital setting : 1o C.
- Digital resolution : 1o C.
- Optional : All S.S Outer & Inner body (on customer requirement)
- Interior : S.S. 304 grade as per requirement
- Power Consumption : 220/230V AC ±10%, 50HZ
- Duty Cycle : COntinous
- Housing Material :CRC/MS Sheet body duly powder coated.
IIC - 121
DIGITAL COLONY COUNTER
Useful
forcountlng Bacterial mould In culture Test/Work.
Provide uniform glaze free illumination
to minimize the strain on eyes
Clearly defines even small colonies.
A100mm (4") dia lens covers the
entire illumination field &its magnification assures high quality
results.
Counting plates with (Wo f hugel) ruling
ensures clearly differentiated & shapely defined Colonies.
Supplied with counting plate, Plate,
Lens, Counting Pen & its cover
Full feature digitally controlled.
Outer casing CRC/MS sheet duly powder
coated.
Applications:
Bio Tech Research, Medical Pharmaceutical & Educational Institute
|
Models |
IIC 121 |
IIC 121 A |
|
3 Digit |
4 Digit |
|
|
Technical Parameters :
- Power Consumption : 220/230V AC supply 50HZ
- Material : CRC / MS Sheet duly powder coated
- Duty cycle : continuous
- Control Panel : MAins & Reset Switch & Fuse.