Environmental Testing Instruments


IIC - 509   HIGH VOLUME SAMPLER
Applications :
HIGH VOLUME AIR SAMPLER. Widely used outdoor air quality monitoring equipment designed for the evaluation of Total Suspended Particulate Matter (TSPM) and obnoxious gases/vapour such as S02, NOs, Ozone, H2S, NH2, Chlorine, etc. in the ambient atmosphere. High Volume Samplers and rugged, inexpensive device with good filtering efficiency that can be operated for long period with minimum maintenance.
DUST SAMPLING
Filteration Assembly Stainless Steel (Grade SS-304) wire netted filter holder and neoprene rubber gasket.
Filter Paper Size 25x20 cm size with effective filtration area 23x18cm
Blower Rating Heavy duty continuous operation type, blower.
Sampling Rate 0.6 to 1.4 m3 air/min.
Particulate Sampling Suspended particulate matter of size 100 micron to 0.1 micron can be collected, depending upon the type of filter media used.
Flow Control By step less electronic controller with indicator.
Flow Measurement By Calibrated orifice plate and glass tube manometer assembly.
Sampling Time Control 24- Hour programmable controller with Autoshut off timer.
Sampling Duration Record By Time Totaliser with capacity to register up to 9999.9 hours.
Power Requirement 220-230 V single phase; 50 Hz AC mains supply.
Built in Voltage Stabilizer Input 140 to 275 V AC/Output 230-10 V AC.
Automatic Shut off Below 170 and above 250 Volts

GAS SAMPLING KIT
Sampling Rate 0.3 to 3.0 LPM Air
Flow Control. By Needle Valve
Flow Measurement By acrylic body Rotameter Calibrated in LPM (Liter in Minute)
Sampling Train Four Sets fo 35ml capacity Impingers.
Impinger Tray Insulated Tray to be used with ice as coolant.



IIC - 510   RESPIRABLE DUST SAMPLER
Respirable Dust Sampler is designed lor the collection of total as well as respirable fraction of the dust present in the out door atmosphere. Measurment of total dust content in the ambient air is used of access the air quality as a Criteria Parameter suggested by Centra/State Pollution Control Board and International Agencies. Dust contents in the ambient air varies from less than 1,0 micron to coarse sand particles which apparently results in the soiling of surfaces, visibility and other problems. Particles ranging from 0.5 to 10 micron are of great significance as they are inhaled during respiratgion causing respiratory diseases.
DUST SAMPLING
Sampling Rate 0.6 to1.4m(3) air/min.
Row Control By stepless electronic controler with indicator
Row Measurement By Calibrated orifice plate and glass tube manometer assembly
Sampling Time Control 24-Hour programmable controller with Auto-shut off timer.
Sampling Duration Record By Time Totaliser with capacity to register upto 9999.9 hours.
Non-Rcspirable Dust Sampling Cyclone assembly separates out and o/collects particles above 10 micron size
Respirable Dust Sampling Respirable dust particles below 10 micron are collected on 25x20cm size filter paper.
Power Requirement 2207230 V single phase; 50 Hz AC mains supply.
Built in Voltage Stabilizer Input 140 to 275 V AC/Output 230-10 V AC
Automatic shut off Below 170 and above 250 Volts.
GAS SAMPLING KIT
Sampling Rate 0.3 to 3.0 LPM Air
Row Control By Needle Valve
Row Measurement By acrylic body Rotameter Calibrated in LPM {Liter Per Minute)
Sampling Train Four Sets of 35ml capacity Glass Impingers.
Impinger Tray Insulated Tray to be used with ice as coolant.



IIC - 511   C.O.D. DIGESTION UNIT
Application :
Impact COD Digestion System is a compact setup designed for the estimation of Chemical Oxygen Demand in water/waste samples. The setup is based on the APHA Method in which sample is digested with sulphuric acid and potassioum dichromate at 150 Deg. C. in a reflusxing assembly to determine the pollution load by measuring theamount of oxygen required to oxidize and convert the organic waste into carbon dioxide and water.

Available In Size :
06 Sampler Digestor.
12 Sampler Digestor.
15 Sampler Digestor.
Model IIC-511 A IIC - 511 B IIC - 511 C
Capacity 6 Samples 12 Samples 15 Samples
Tube Size 40x200mm with B14 Interchangeable Socket.
Condenser 640 mm with bulb, funnel and B-34 Interchangeable Cone.
Timer/Process Programmable electronic digital timer.
Temp. Range 5 Deg. C. above ambient to 200 Deg. C.
Temp. Controller Microprocessor based programmable Digital Temperature Indicator-cum-Controller with 7 Segment L.E.D. Display Pannel.
Safety features Over Temperature Proctection, and Autotuning provision.
Power 230 V 50 Hz AC mains.
Optional
  • Glass Digestion Vessel.
  • Glass Refluxing Condensor.