General Lab Instruments


IIC - 166   CANNING RETORT
With Pressure Gauge, With Safety Valve, With Release Valve.

Available In Size
Suitable to hold 21 cansof A2-1 /2size -1 IC 166 A.
Suitable to hold 75 cans of A 2-1 /2size. - IIC 166 B.
Suitable to hold 90 cans of A 2-1 size. - IIC 166 C.
Suitable to hold 280 cans of A2-/2size - IIC 166 D.



IIC - 167   AUTOMATIC FLASH POINT APPRATUS (Price on Request)
IMPACT Automatic flash point and fire-point test method is a dynamic method and
     depends on definite rates of temperature increases to control the precision of the
     method.

Its primary use is for viscous materials having a flash point below79°C (175°F)
     except fuel oils, to define the hazards of flammable and combustible materials used
     in shipping and safety regulations. The temperature of the approximately 70 ml test
     specimen is increased rapidly at first and then at a slower constant rate as the flash
     point is approached. At specified intervals a test flame is passed across the cup, to
     measure the tendency of the test specimen to form a flammable mixture with air
     under controlled laboratory conditions.

The flash point is the lowest liquid temperature at which application of the flame
     causes the vapors of the test specimen of the sample to ignite.

To determine the fire-point, the test is continued until the application of the test flame causes the test specimen to ignite
     and sustain burning for a minimum of 5s

It is an automatic flash and fire-point tester used to examine liquid as well as highly viscous samples in the same
      instrument without any additional equipment for temperature range up to 400°C. For substances with unknown flash
     points, the APPARATUS has a special search mode program.

During the entire heating period, the test flame is moved across the sample at suitable intervals. The expected flash
     point of a specimen can there by be found in a time saving and economical manner.

Optional

The UNIT is equipped with:
Standard Cup :   with handle, made of brass
Temperature Probe Pt-100 :    For sample temperature
Battery operated (1.5 V pencil type cell) Gas igniter :    For LPG gas ignition (Manually operated)
Flame Detection Unit :    For the detection of flash- and fire-points by UV sensor.
Heating :    By electrical SS Tubular Cartridge Heater of suitable rating to maintain ramp rate & easily
DC Motors :    Flame Arrest Coverfor extinguishing the fire in the cup : Flame movement, LID Open/Close, Assembly of sensor RTD(Pt-100 thermocouple) Up/Down mechanism PC Interface Programmed ControllerThe Unit is incorporated with MODBUS RTU PC interface Microprocessor based PID Programmable controller userfriendly features.(PC operated system through RS232 cable connection as option at extra cost)

IMPACT" Automatic Flash and Fire point apparatus (By Cleveland Open Cup Method)

Temp Range :    Ambient to 400°C with RTD sensor as Thermocouple
Flame-Detector :    UV based flame-detector sensor & Controller
DC motors :    Flame movement, LID Open/Close, Assembly of sensors Up/Down mechanism. Microprocessor based Program process controller cum indicator with 3-wire RTD temperature sensor, free potential flame detector sensor as i/p and DC V SSR
Controller :    As o/p.
Equipment Overall Size (LxWxH) :    24"x14"x31"
Equipment Gross Weight :    21 Kg.
Supply :    230 V, 1-0,50 Hz supply with proper earthing system for Controller.



IIC - 168   DIGITAL ABEL FLASH POINT APPRATUS
This method determines the dosed cup flash points of petroleum products and mixtures to ascertain whether they give off inflammable vapour below 73°F or 49°C. The instrument comprises of electric heater at bottom and is supplied with a water bath cup coverfitted with stirrer, Digital Temperature Indicator & Electronic Temperature Regulator, sockets & stand.