Home » Analytical testing Instruments

Analytical testing Instruments


IIC -409   MICROPROCESSOR UV-VIS SPECTROPHOTOMETER SINGLE BEAM
Applications :
UV- visible spectrophotometer, an analytical instrument commonly used in physico-chemical laboratories to make quantitative and qualitative analysis of specimen materials in the utraviolet. Visible spectral range finds much scope for its service in such fields as medicine. Clinical examination, biochemistry, petro-chemical industry Bio technology, Environmental protection and quality control.The technique has enjoyed a molecular buology and the need to quantify DNA and proteins. Here, the simplicity of use, the non-destructive nature of the sampling and the cost effectiveness of the measurement has proved very beneficial in the modern laboratory.

SALIENT FEATURES
  • Covers 195 to 1000nm
  • 4 position cuvettes holder
  • Rs-232C computer interface
  • High wavelength precision
  • Compacts good looking shape
  • Highly accurate & stable
  • ABS for the accurate measurement of the value and C
  • Figures show measured value four LCD
  • Imported material dueterium lamp, tungsten lamp
  • Sample chamber can be placed 5 mm-100mm samples
  • A key value of automatic calibration ABS
  • Rs 232, can be connected to the computer and printer
  • SPECTRAL WAVELENGTH : 195to1000nm
  • SPECTRAL BANDWIDTH : 2 nm
  • ACCURACY : :±0-5nm
  • REPEATABILITY : :±0-3nm
  • RESOLUTION : 0.1 nm

STANDARD PACKING
  • Main set : 1 No.
  • Rs 232 cable : 1 No.
  • Accessory Kit, including a 4 glass cell (1cm) : 1 No
  • Quartz Cell (1cm) : 4 No.
  • Operating manual : 1 No.
  • Dust Cover : 1 No.
  • Software CD : 1 No.
photometric range 0-200%T, -0-301-2.000A, 0-1999C
accurancy ±0.005 Abs at 1.0 Abs
± 0.010 Abs at 1.5 Abs< 0.3%T@
stray light 220 nm.360nm
data output Rs-232
readability ± 1 Count
data readout Single Line LCD display
key board 4 keys, Soft touch membrance type
printer interface Printer interface for any Centronics dot matrix printer
serial interface Rs 232C interface
Light Source Philip halogen, dueterium lamp (2000h)
Detector Wide range Silicon Photodiode
Optics Complete mirror optics with resolution
1200 grooves@mm grating.
Sample Holder 4 position adjustable sample holder
Absorbance Measurement Range 0.000A-1.999A
Concentration Direct-reading Range 0000-1999
K Factor 0 to 1999
Transmittance Accuracy < 0-5%3min
Transmittance Reproducibility 0.5%
Transmittance Measurement Range 0.0%-199.9%
Noise 100% < 0.3%T: 0% < 0.1 %
Stability < 0.002A/h@500nm
Power 230V±10%,50 Hz. AC
Dimensions 540(L)X 470 (W)X320 (H)
Weight 11kg
Interface RS-232, Centronics & computer
Print format All Data & Date Wise (Programmable)
Digital output Serial RS-232 Parallel Centronics (Programmable)
Error Indication pH ERROR.ORP ERROR.CAL ERROR & TERROR
Accessories pH electrode Instruction Manual Buffer Solutions
Dust cover Electrode Stand Temp Probe

Appearance & Specification subjected to change due to continuous development Print Format:-
DATE TIME TEMP(DegC) PARAMETER MODE SRNo
12/12/08 11:18 T= 020.0 pH= 07.00 MANUAL 001
12/12/08 11:18 T= 020.0 mV= 0000 MANUAL 002
12/12/08 11:18 T= 020.0 T= O2O.O0C MANUAL 003
DATE TIME TEMP(DegC) PARAMETER MODE SRNo
12/12/08 11:18 T= 020.0 pH= 07.00 MANUAL 001
12/12/08 11:18 T= 020.0 mV= 0000 MANUAL 002
12/12/08 11:18 T= 020.0 T= O2O.O0C MANUAL 003



IIC - 410   Microprocessor Visible Spectrophotometer
Visible Spectrophotometer models are designed for reliable continuous operation. It is easy to use, throughly reliable and above all low cost.
  • The monochromator with a holographies flashing grating is used.
  • It has the advantage of high wavelength precision, good monochromaticity and low stray light.
  • A sample compartment for 0.5cm-10cm cells.
  • Computer control system, precise automatic T/A changeover
  • Automatic Zero and full scale adjustment.
  • Direct concentration read-out and concentration factor setting function.
  • Equipped with RS 232 port. Data can be sent to PC by special software.

Applications:
  • Medicine/Pharmaceutical
  • Commodity Inspection
  • Agricultural Chemistry
  • Mettallurgy
  • Machine Manufacturing
  • water, and waste water Labs
  • Industry Environmental Monitoring
  • Food Inspection
  • Teaching in Collages & Universities
  • Geology
  • Petrochemical Industries
  • Food and Beverage Labs4

Technical Parameters
Wavelength Range : 325-1000nm
wavelength Accuracy : <2 nm
Wavelength Repeatability : <1nm
Transmittance Accuracy : ±0.5%
Transmittance Repeatability < 0.2%
Spectrum Bandwidth : 2 nm/1 nm
Stray Light : <0.5% {at 360 nm, NaNo,
Light Current Drift : 0.5% /3min
Dark Current Drift 0.2%/ 3 min
Cell Holder 10nm
Dimensions 56 x 48 x 29 cms
Net Weight : 13.5 Kgs
Gross weight : 27 Kgs
STANDARD CONFIGURATION
  • Main Instrument : 1 unit
  • Operational Manual : 1 pc
  • Glass Cell 10 mm : 4 pes
  • Power Cable : 1 pc
  • Fuse(3A) : 2 pes
  • Software CD : 1 no.
  • Software Key : 1 no.
Optional
  • 5/10/20/50MM Glass Cell
  • 5/10/20/50MM Quartz Cell
  • 50 mm Cell holder 100 mm Cell holder
  • Tungsten-halogen lamp (12V 30W)