IIC - 107
      Humidity / Stability Test Chamber
    
      
        |  | 
      
        |  | 
      
        |  | 
    
     Precise Hot Air
    & Humidity.
     
     Better Mineral I Put Insulation Keep the
    surface Temperature comfortable & Avoid Heat & Humidity Loss.
     
     Silent Hot Air Blower, Unique design of
    Air Circulation & Humidity circulation & improved Temperature /
    Humidity distribution. 
     
     Unique design of Ventilation.
     
     304 grade of S. Steel interior Corrosion
    resistant long life operation.
     
     Kanthal A-1 Tubular heater is fitted for
    better circulation.
     
     Safety controller are provide with
    Digital Temp. Controller Cum Indicator.
     
     Kanthal A-1 steel Tubular heater is
    fitted in the steam Bath for long life & better result.
     
     Full feature with Temp. Controller i.e.
    Thermostat Bi-Metallic Capillarytype for both Dry & Wet Temp. Control or
    Digital Temp. Controller Cum Indicator & Microprocessor Based PID Temp.
    Controller cum Indicator. 
     
     Choose among the models with window
    front glass door or inner Perspex/Acrylic sheet Door with full view to
    observe the Test process inside the chamber while keep Temperature
    uninterrupted. 
     
     Angle Iron frame with castor wheel for
    easy movement (for Refrigerated model).
     
     Fitted with 02 Nos. Fan for cooling &
    heating (For Refrigerated Model).
     
     Filled with 02 Nos. Circulation motorfor
    water injection in routine model inside the control unit & Chamber.
     
     Humidistat is placed inside the chamber
    to control requested humidity.
     
     Humidity can be controlled by Digital
    Temp. & Humidity (Both automatically on customer requirement).
     
     Wet Temp, is controlled by
    Bi-MetallicThermostat Connected to Water Bath placed in the control unit
    having water level. (Nozzle for Water inlet & outlet & overflow). 
     
    Applications: :
     Tissue Culture, Pharmaceuticals, Agriculture, Cable Industry, Paper, PVC &
    Cement industries Electrical Industries.
    Only Heating(Ambient to 50 Deg C)
    
      
        |  | 
          
            | Models | IIC 107 | IIC 107 A | IIC 107 B | IIC 107 C |  
            | Capacity (Liter) | 112 Ltrs. | 171 Ltrs. | 280 Ltrs. | 340 Ltrs. |  
            | Volume | 4 Cuft | 6 Cuft | 10 Cuft | 12 Cuft |  
            | Interior (mm) | 455 x410x610 | 505 x415 x830 | 570 x 550 x 875 | 650 x 580 x 900 |  |  | 
    
    
    
     
    
    Technical Parameters :
    
      - Temperature Range : Ambient to 50° C
- Temperature Stability : 1° C max
- Material : CRC/ Mild Steel Sheet Duly Powder Coated 220/230 V 
- Power Consumption : AC ±10%, 50HZ single Phase Water Level or
        Low level 
- Safety Function Interior : cut off Alarm (On Demand) Stainless Steel
        304 Grade 
- Humidity Range : Ambient to 95%± 3%
- Optional : Digital Timer
- Precaution : Don't use the Instrument without Water
Both Cooling & Heating (10Deg C to 50 Deg C) 
    
    
    
    
      
        |  | 
          
            | Models | IIC 107-1 | IIC 107-1 A | IIC 107-1 B | IIC 107-1 C ! |  
            | Capacity (Liter | 112 Ltrs. | 171 Ltrs. | 280 Ltrs. | 340 Ltrs. |  
            | Volume | 4 Cuft | 6 Cuft | 10 Cuft | 12 Cuft |  
            | Interior (mm) | 455 x410x610 | 505 x415 x830 | 570 x 550 x 875 | 650 x 580 x 900 |  |  | 
    
    Technical Parameters :
    
      - Temperature Range : 10°to50°C / 0°to50°C
- Temperature Stability : 1° C or Better
- Material : CRC/ Mild Steel Sheet Duly Powder Coated 
- Power Consumption : 220/230 V AC +/-10%, 50HZ single Phase
- Safety Function : Water Level or Low level cut off Alarm
- Interior : Stainless Steel 304 Grade
- Humidity Range : 55% to 95% +/- 3%
- Compressor : Kirloskar/Equivalent as per required Model 
- Voltage Stablizer : Automatic InbuildStablizer (Optional
- Refrigerated : R 134/22
- Optional : Digital Timer
- Precaution : Don't use the Instrument without Water